NEW QUESTION 44
How many 12v batteries can the optional battery inspection instrument of UPS5000-A-400/500K support?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 45
FusionModule500&FusionModule800 remote WEB interface monitoring must be configured with unified network management software.
- A. False
- B. True
Answer: B
NEW QUESTION 46
One NetCol520 chilled water distribution units can maximum support () NETCOL5000-C water-cooled row-level precision air conditioners.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 47
Which of the following are indoor products of Huawei data center solutions? (Multiple choice)
- A. FusionModule500
- B. FusionModule1000A
- C. FusionModule1000B
- D. FusionModule2000
- E. FusionModule800
Answer: A,D,E
NEW QUESTION 48
What items need to be checked after the UPS5000-E system is installed? (Multiple choice)
- A. Whether the cable layout considers other system wiring in the future
- B. Whether the mechanical installation of UPS and battery system is firm
- C. The positive and negative connections of the battery are correct
- D. If the ground wire connection is reliable
Answer: A,B,C,D
NEW QUESTION 49
What is the possible cause of the high discharge temperature of the NETCOL5000-A air conditioner compressor? (Multiple choice)
- A. Too little refrigerant charge
- B. Refrigerant circuit or device blockage
- C. The condenser is dirty and blocked, resulting in poor heat dissipation
- D. The installation position of the outdoor unit is wrong
Answer: A,B,C,D
NEW QUESTION 50
Which of the following functions does PDU8000 precision power distribution cabinet mainly have? (Multiple choice)
- A. Power distribution function of data center micro-module (cabinet)
- B. Protection function of the lower line and equipment of the precision power distribution cabinet
- C. Main circuit and sub-circuit metering function of precision power distribution cabinet
- D. The precision power distribution cabinet supports SNMP and MODBUS communication, which can transmit information to the intelligent monitoring system.
- E. Abnormal alarm function of main circuit and sub-circuit of precision power distribution cabinet
Answer: A,B,C,D,E
NEW QUESTION 51
What are the possible reason of the excessive noise of the NETCOL5000-C fan? (Multiple choice)
- A. The filter is dirty and blocked
- B. Loose fan installation
- C. The air outlet of the fan is dirty and blocked
- D. Fan failure
Answer: A,B,C,D
NEW QUESTION 52
The terminal power of the battery in the open circuit state is called ().
- A. Rated voltage
- B. Discharge voltage
- C. Open-circuit voltage
- D. Actual voltage
Answer: C
NEW QUESTION 53
UPS5000-E (50kVA module) series UPS does not derate backup power, the number of 12V batteries in the following configuration, which is unreasonable?
- A. Section 38
- B. Section 34
- C. Section 40
- D. Section 36
Answer: C
NEW QUESTION 54
The dry contact signal of UPS5000-E does not support the remote emergency stop function.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 55
Which of the following description of UPS5000-A is correct? (Multiple choice)
- A. Modular
- B. Backup UPS
- C. Power frequency
- D. Double Transform Online
- E. High frequency
- F. Tower
Answer: D,E,F
NEW QUESTION 56
( ) indicates the amount of electricity that a fully charged battery can release when it is discharged to the specified mid-branch voltage according to certain discharge conditions. The unit is expressed in AH or WH.
- A. Rated capacity
- B. Maximum capacity
- C. Actual capacity
- D. Minimum Capacity
Answer: C
NEW QUESTION 57
UPS5000-E only needs to select ( ) to easily realize the N+X power supply system. The operation is simple and convenient. (Fill in the blank)
- A. Parallel cable
Answer: A
NEW QUESTION 58
The NETCol5000-A36W air conditioner has a light load initial function.
- A. False
- B. True
Answer: A
NEW QUESTION 59
The default management authority user name of the ECC800 is admin, and admin has all the authority to operate the WEB interface functions.
- A. False
- B. True
Answer: B
NEW QUESTION 60
Fusionllodule2000 UPS is listed and configured?
- A. Integrated UPS cabinet
- B. Precision power distribution cabinet
- C. Integrated power distribution cabinet
Answer: A
NEW QUESTION 61
What are the possible reasons for the failure of the humidification function of the NETCOL5000-A air conditioner? (Multiple choice)
- A. Humidifier circuit is not closed
- B. The outdoor unit is not running
- C. The indoor temperature is low
- D. Humidifier damage
Answer: A,B,D
NEW QUESTION 62
The AI/DI port on the access control actuator supports to connect the ().
- A. Fingerprint Reader
- B. IC card reader
- C. Door open button
- D. Electronic magnetic lock
Answer: C
NEW QUESTION 63
Which of the following statements about the reliability of UPS5000-A (30kVA~120kVA) are correct? (Multiple choice)
- A. Inverter overload capacity is strong
- B. Ultra-wide input voltage range
- C. Three anti-paint coating technology
- D. 6kV/5kA lightning protection design
Answer: A,B,C,D
NEW QUESTION 64
When the NetCol8000-C room-level chilled water intelligent temperature control product is booted, which model will it give priority to use? (Multiple choice)
- A. 190D
- B. 150D
- C. 130D
- D. 160D
Answer: A,C
NEW QUESTION 65
UPS5000-A has built-in SNMP and ModBus card to reduce the management investment cost of customers.
- A. False
- B. True
Answer: B
NEW QUESTION 66
How many temperature and humidity monitoring modules are required for each temperature control product?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION 67
In the UPS5000 configurator, what are the optional module types? (Multiple choice)
- A. 50k standard effect
- B. 60k
- C. 50k high efficiency
- D. 25k
Answer: A,B,C,D